Reversing Contactor, TeSys K, 3P, AC-3/AC-3e,440V 12A, 1NO, 24V DC low consumption coil

Code: LP5K-1210-BW3

Futura Electronics stockists of Schneider LP5K-1210-BW3, Contactor. Complete range of Reversing Contactor available online & in-store.

From 75.00 ex VAT

In Stock



Quantity Breaks (per unit)
1 to 19 €82.00
20 to 49 €77.00
50 + €75.00

Schneider LP5K-1210-BW3 | Contactor

Contactors | Relays & Switches

Range TeSys
Product name TeSys K
product or component type Reversing contactor
Device short name LP5K
Device application Control
contactor application Motor control
Resistive load Utilisation category AC-4 ,AC-1, AC-3, AC-3e
device presentation Preassembled with reversing power busbar
poles description 3P
power pole contact composition 3 NO
[Ue] rated operational voltage Power circuit: 690 V AC 50/60 Hz, Signalling circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current 20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit, 16 A (at <70 °C) at 690 V AC AC-1 for power circuit, 12 A at <= 440 V AC AC-3 for power circuit, 12 A at <= 440 V AC AC-3e for power circuit
Motor power kW 4 kW at 480 V AC 50/60 Hz, 4 kW at 500...600 V AC 50/60 Hz, 4 kW at 660...690 V AC 50/60 Hz, 3 kW at 220...230 V AC 50/60 Hz, 5.5 kW at 380...415 V AC 50/60 Hz, 5.5 kW at 440 V AC 50/60 Hz
Control circuit type DC low consumption
[Uc] control circuit voltage 24 V DC
auxiliary contact composition 1 NO
[Uimp] rated impulse withstand voltage 8 kV
Overvoltage category III
[Ith] conventional free air thermal current 20 A (at 50 °C) for power circuit, 10 A (at 50 °C) for signalling circuit
Irms rated making capacity 110 A AC for signalling circuit conforming to IEC 60947, 144 A AC for power circuit conforming to NF C 63-110, 144 A AC for power circuit conforming to IEC 60947
Rated breaking capacity 110 A at 440 V conforming to IEC 60947, 80 A at 500 V conforming to IEC 60947, 70 A at 660...690 V conforming to IEC 60947
[Icw] rated short-time withstand current 115 A 50 °C - 1 s for power circuit, 105 A 50 °C - 5 s for power circuit, 100 A 50 °C - 10 s for power circuit, 75 A 50 °C - 30 s for power circuit
55 A 50 °C - 1 min for power circuit, 50 A 50 °C - 3 min for power circuit, 80 A - 1 s for signalling circuit, 90 A - 500 ms for signalling circuit, 110 A - 100 ms for signalling circuit, 25 A 50 °C - >= 15 min for power circuit
Associated fuse rating 25 A gG at <= 440 V for power circuit, 25 A aM for power circuit, 10 A gG for signalling circuit conforming to IEC 60947, 10 A gG for signalling circuit conforming to VDE 0660
Average impedance 3 mOhm - Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltage Power circuit: 600 V conforming to UL 508, Power circuit: 690 V conforming to IEC 60947-4-1, Signalling circuit: 690 V conforming to IEC 60947-4-1, Signalling circuit: 690 V conforming to IEC 60947-5-1, Signalling circuit: 600 V conforming to UL 508, Power circuit: 600 V conforming to CSA C22.2 No 14,  Signalling circuit: 600 V conforming to CSA C22.2 No 14
Electrical durability 1.3 Mcycles 12 A AC-3 at Ue <= 440 V, 1.3 Mcycles 12 A AC-3e at Ue <= 440 V, 0.3 Mcycles 20 A AC-1 at Ue <= 690 V, 0.02 Mcycles 72 A AC-4 at Ue <= 440 V
Interlocking type Mechanical
mounting support Plate, Rail
Standards EN/IEC 60947-4-1, GB/T 14048.4, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1
Product certifications CB Scheme, CCC, UL, CSA, EAC, CE, UKCA
Connections - terminals Screw clamp terminals 1 cable(s) 1.5…4 mm²solid, Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end, Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end, Screw clamp terminals 2 cable(s) 1.5…4 mm²solid, Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end, Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
Tightening torque 0.8…1.3 N.m - on screw clamp terminals Philips No 2, 0.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm, 0.8…1.3 N.m - on screw clamp terminals pozidriv No 2
Operating time 10...20 ms coil de-energisation and NO opening, 30...40 ms coil energisation and NO closing
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 5 Mcycles
Maximum operating rate 3600 cyc/h
Complementary Coil technology
Built-in bidirectional peak limiting diode suppressor 
Control circuit voltage limits Operational: 0.7...1.30 Uc (at <50 °C), Drop-out: 0.1...0.7 Uc (at <50 °C)
Inrush power in W 1.8 W (at 20 °C)
Hold-in power consumption in W 1.8 W at 20 °C
Heat dissipation 1.8 W
Auxiliary contacts type Type instantaneous 1 NO
Minimum switching current 5 mA for signalling circuit
Minimum switching voltage 17 V for signalling circuit
Non overlap distance 0.5 mm
Insulation resistance > 10 MOhm for signalling circuit